Home >> Tests & Reports  >> Infra-Red Report >> Ceiling (4)


Infrared Thermography Report

Client:
A' Real Insulation
Contact:
Colin Blumenthal
Operator:
Ian Davidson
Job date:
29-Apr-02
Page:
7
Roof Space
ID
MeanT
Min
Max
Location
Roof space temps outside heated room
R1
15.21
14.68
15.83
Area Temperatures
Item ID
Ceiling panel with & without insulation
R2
20.01
18.68
22.45
Object Parameter Variables
29-04-02
Survey Date
9.00 am
Time
ID
Temp
Min
Max
1m
Object Distance
LI
15.19
14.71
15.74
Graph Temperatures
90%
Humidity
L2
20.76
20.19
22.19
16 deg
Ambient Temperature Out
L3
15.95
14.83
21.66
0.9
Emissivity
L4
16.3
14.91
21.54
Celsius
Displayed Temperature