GRAYSON TEST February 1994
Comparative corrosion tests between Insul-Fluf and a well known fibreglass insulation in accordance with NZS 4222:1992 Appendix A.
The results were as follows:
Metal Coupon
Thickness
Metal Grade
Effects of Fibreglass
Effects of Insul-fluf
Copper
0.1mm
Cabra No.110 Soft Copper
Some small - medium
areas of corrosion leaving black deposit
Some very small areas of surface corrosion
Aluminium
0.08mm
-
Large areas of corrosion on 1 side of coupon - not all the way through
Small areas of slight surface corrosion
Steel
0.08mm
Shim steel
Extensive corrosion
especially on corners – small holes on one corner
Virtually no corrosion evident
Galvanised Steel
1.5mm
Standard wall framing member galvanised steel
Some small areas of surface corrosion.
Some small areas of surface corrosion.